Gold Coast – fixed price – 24/7
A safety switch can trip on its test button and still be too slow to protect you. We test your RCDs with proper equipment so you know they'll do their job. Many landlords, workplaces and homeowners rely on safety switches that have never been tested.
Safety switch won't stay on?Leave it off and call an electrician. If anyone has had a shock, call 000.
Call 0421 333 034A timed trip test with a meter checks how fast each safety switch trips. The test button only shows that it can trip.
You should still press each test button every three months.
We test your safety switches with a meter, explain the results, and quote a fixed price for any that fail.
We find your safety switches and what each one protects, then trip-test them with a meter.
Each safety switch tripped with a test meter and its trip time measured, not just the button pressed.
We tell you which switches passed, which need attention, and what each one protects.
If a switch fails, we tell you and give you a fixed price to replace it.
Power point circuits with no protection? We fit safety switches or RCBOs.
Switchboard upgradesWe look for the circuit or appliance that's tripping the switch.
Why it keeps trippingCircuits tested in sequence, planned around how your site operates.
Strata electriciansFrom the Electrical Safety Regulation 2026, in force since 1 September 2026, and Queensland's Electrical Safety Office.
You have 90 days from taking possession to fit a safety switch to the power point circuits. The seller must tell you in writing whether there is one.
Source: Electrical Safety Regulation 2026, ss 26 and 28
No safety switch on the power points? You have 90 days from the start of a new tenancy to fit one.
Source: Electrical Safety Regulation 2026, s 29
With a few exceptions, such as emergency or safety work, an electrician can't do installation work in a home with no safety switch on the power points unless the job includes fitting one.
Source: Electrical Safety Regulation 2026, s 30
If the switch doesn't trip when you press the button, it's faulty. Get a licensed electrician to check it.
Source: Electrical Safety Office
The regulator recommends safety switches on all circuits: power points, lighting, air conditioning, stove, hot water and pool equipment. The sale and rental rules cover power points only.
Source: Electrical Safety Office
The regulation has workplace safety switch rules that vary by type of work, including office, service, manufacturing and construction work. Ask us which apply to your site.
Source: Electrical Safety Regulation 2026, pt 6
A plain-English summary, not legal advice. Selling? Read do you need a safety switch to sell a house in QLD.
Tell us about the property and its boards.
One figure before work starts. No hourly rate.
We tell you which circuits go off, and when.
Each one trip-tested with a meter.
Passes, fails and a fixed price for any replacements.
EFTPOS on site when you're happy.
For larger jobs over $5,000 in materials that span multiple days, a deposit may be requested when the quote is accepted.
We quote once we know what's on site. These are the things that move the number.
Commercial and strata
Testing a safety switch turns off the circuits it protects. For shops, offices and strata buildings, we test in sequence and tell you before anything switches off.
We inspect first. The quote is the number you pay.
If our work fails, we come back and fix it.
Based in Palm Beach, so same-day is often possible.
QLD Electrical Contractor Licence, fully insured.
Residential, commercial and industrial work.
Paid on site when the job's done. No invoice to chase.
Director, Knight Electrical Solutions
20+ years in electrical work across Australia and New Zealand, including running his own business in Auckland.
Questions Gold Coast homeowners, landlords and businesses ask us about safety switches.
At home, press the test button on each safety switch every three months. That's the Electrical Safety Office's advice. Workplaces have separate rules under the Electrical Safety Regulation 2026 that depend on the type of work. The button only shows a switch can trip. A timed test with a meter measures how fast it trips, so it's worth having one done by a licensed electrician.
Not completely. The button proves the switch can trip. It doesn't measure how quickly it trips when current leaks to earth, which is what protects someone from a shock. A switch can pass the button test and still be slow. A timed trip test uses a meter to pass a small test current and measure the response. Keep pressing the button every three months, and consider a timed test too.
For many homes, yes. Under the Electrical Safety Regulation 2026, a new owner must have an approved safety switch on the power point circuits within 90 days of possession, and a landlord within 90 days of a new tenancy. With a few exceptions, an electrician also can't do installation work in a home without one unless the job includes fitting it. Those rules cover power points, but the regulator recommends all circuits.
We tell you and give you a fixed price to replace it. Until it's replaced, the circuits it covers may have no earth leakage protection. If you press the test button at home and the switch doesn't flick off, the Electrical Safety Office says it's faulty and you need a licensed electrician to check it. Don't assume a switch that hasn't tripped in years is working.
It depends on the property, so we quote once we know what's there. The main factors are how many safety switches and RCBOs you have, how many boards and sub-boards they're spread across, the type of site, and whether testing has to happen after hours. You get one fixed price before work starts, with no hourly rate. Any failed switch is quoted separately.
Often an appliance or circuit is leaking current to earth, and the safety switch is doing its job. Water in outdoor power points, a failing hot water element or a worn appliance are common causes. You can try resetting it once. If it trips again straight away, leave it off and call a licensed electrician. Don't keep resetting it, and never bypass it.
Generally the business running the workplace. The Electrical Safety Regulation 2026 requires a person conducting a business or undertaking to manage electrical risks at the workplace, and Part 6 sets safety switch rules that vary by type of work. Keeping track of when tests are due is the part that often slips. Tell us about your site and the work done there, and we'll quote the testing.
Mostly, yes. Each test trips the circuits that switch protects, so we test in sequence and plan the order around how you operate. We tell you before anything switches off. Circuits feeding critical equipment such as fridges, servers or medical gear can be tested outside trading hours. For strata buildings, we can test common property boards with the price agreed before work starts.
Our electricians cover the whole Gold Coast and Tweed Heads.
We'll trip-test your safety switches, explain the results, and fix the price of any repairs before we start.
0421 333 034
If anyone is in danger, has had an electric shock, or you can see fire, sparks or fallen powerlines, call Triple Zero (000) immediately. Don’t touch anyone who may be in contact with live electricity.
The information on this page is general and is not advice for your property. Summaries of Queensland law and standards are drawn from the official sources linked on this page, and may change; the official sources prevail. Regulations, Australian Standards and safety requirements change, and errors can occur, so have a licensed electrician assess your situation in person before acting on anything here. Electrical work in Queensland must only be done by a licensed electrician. If you think something here is wrong or out of date, call 0421 333 034 or email byron@knightes.au and we'll review it. To the extent permitted by law, Knight Electrical Solutions accepts no liability for loss or damage arising from reliance on this information.