Gold Coast – fixed price – 24/7
Breakers tripping. Lights flickering. A board that's warm to the touch, or still running ceramic fuses. We test it, show you what we found, and quote a fixed price to bring it up to current Queensland standards.
Board hot, sparking or smelling of burning?Don't touch it. Fire or an electric shock: call 000 first.
Call 0421 333 034You may need a switchboard upgrade if your board has ceramic fuses, has no safety switch on the power points, or trips for no clear reason.
Adding an EV charger, battery or ducted air conditioning? The board may need upgrading first.
Not sure? We'll test it and tell you straight, with a fixed price before any work starts.
Read why a switchboard keeps tripping or what a buzzing board means.
Most jobs start with a test. The results tell us whether you need a repair, new safety switches or a full replacement.
We test the board and its safety switches. A thermal scan can show connections running hot.
What a thermal scan findsBurnt terminals, failed breakers and water-damaged boards, repaired where a repair makes it safe.
Old fuses out, circuit breakers and safety switches in, tested once the work is done.
With an RCBO on each circuit, one fault trips that circuit, not the whole house.
Safety switch testingBoard and load checks before a new charger or battery goes in.
EV charger installationWe check the main earth and repair it if it fails testing.
Switchboard and meter box jobs from our team around the Gold Coast.




From the Electrical Safety Regulation 2026, in force since 1 September 2026, and Queensland Government guidance.
You have 90 days from taking possession to fit a safety switch to the power point circuits. The seller must tell you in writing whether there is one.
Source: Electrical Safety Regulation 2026, ss 26 and 28
No safety switch on the power points? You have 90 days from the start of a new tenancy to fit one. It's easiest between tenants.
Source: Electrical Safety Regulation 2026, s 29
With a few exceptions, such as emergency or safety work, an electrician can't do installation work in a home with no safety switch on the power points unless the job includes fitting one.
Source: Electrical Safety Regulation 2026, s 30
Switchboard panels and meter boards made or imported before 2004 may contain asbestos. Don't drill, cut or work on one yourself. We'll tell you what to expect and who's needed.
What to expectYour retailer arranges the new meter. The switchboard and meter box are still your responsibility and cost.
Press each test button every three months. If the switch doesn't trip, it's faulty. Get a licensed electrician to check it.
Source: Electrical Safety Office
A plain-English summary, not legal advice. Selling? Read do you need a safety switch to sell a house in QLD.
Tell us what the board is doing.
We test the board and tell you what we find.
One figure before work starts. No hourly rate.
We agree a time and tell you how long the power's off.
Tested once the work is done.
EFTPOS on site when you're happy.
For larger jobs over $5,000 in materials that span multiple days, a deposit may be requested when the quote is accepted.
We don't price a switchboard until we've seen and tested it. These are the things that move the number.
Read our switchboard cost guide
Commercial and strata
For shops, offices and strata buildings, we plan the shutdown with you, can work outside trading hours, and fix the price before work starts.
We inspect first. The quote is the number you pay.
If our work fails, we come back and fix it.
Based in Palm Beach, so same-day is often possible.
QLD Electrical Contractor Licence, fully insured.
Residential, commercial and industrial work.
Paid on site when the job's done. No invoice to chase.
Director, Knight Electrical Solutions
20+ years in electrical work across Australia and New Zealand, including running his own business in Auckland.
Questions Gold Coast homeowners and businesses ask us about switchboards.
Ceramic fuses, no safety switch on the power point circuits, regular tripping and no space for new circuits are the usual signs. So is a plan to add an EV charger, home battery or more air conditioning. A board that is hot, buzzes, looks scorched or smells of burning plastic needs an electrician urgently. If you're not sure, we test the board on site and tell you plainly whether it needs work.
For many homes, yes. Under the Electrical Safety Regulation 2026, a new owner must have an approved safety switch on the power point circuits within 90 days of taking possession, and a landlord within 90 days of a new tenancy starting. With a few exceptions, a licensed electrician also can't do installation work in a home that has none unless the job includes fitting one. Those rules cover power points, but we recommend protecting lighting circuits too.
Often a loose connection, a breaker failing inside, or a circuit carrying more load than it should. Each of those makes heat, and heat in a switchboard can be a fire risk. Don't open the board or touch it. If there's smoke, sparks or flame, get everyone out and call 000. Otherwise call a licensed electrician. We can test the board and use thermal imaging to look for hot spots.
Many house boards can be replaced in a single visit, with the power off for part of the day. Bigger boards, a meter box change or faulty circuits found during testing can add time. We tell you how long the power will be off when we quote and book the shutdown for a time that suits you. For businesses we can do the changeover outside trading hours.
It depends on the board, so we don't give a price before we've seen it. The main factors are how many circuits you have, how many safety switches they need, whether the meter box has room or must be replaced, the condition of the wiring we test, and whether the old panel may contain asbestos. We inspect, then give you one fixed price before work starts. No hourly rate, and you pay on completion by EFTPOS.
Often, but not always. An EV charger or battery usually needs its own circuit and space on the board, and your supply has to carry the extra load. Older boards with fuses or no spare room usually need upgrading first. We check the board and the supply before quoting, so you know up front whether the charger or battery can go straight in.
It's possible. The Queensland Government's asbestos website says switchboard panels and meter boards made or imported before 1 January 2004 may contain asbestos, and most boards installed before 1990 are very likely to. Drilling or cutting asbestos can release fibres, so never work on an old board yourself. Before any work starts, we explain what to expect, including whether a licensed asbestos removalist needs to be involved.
A fuse has a wire that melts when a circuit overloads and must be rewired or replaced. A circuit breaker does the same job but switches off and can be reset. Both protect the wiring. A safety switch (RCD) protects people: it cuts the power in a fraction of a second when current leaks to earth, for example through someone touching a live part. An RCBO combines a breaker and a safety switch on one circuit.
Our electricians cover the whole Gold Coast and Tweed Heads.
We'll test it, show you what we find, and give you a fixed price before any work starts.
0421 333 034
If anyone is in danger, has had an electric shock, or you can see fire, sparks or fallen powerlines, call Triple Zero (000) immediately. Don’t touch anyone who may be in contact with live electricity.
The information on this page is general and is not advice for your property. Summaries of Queensland law and standards are drawn from the official sources linked on this page, and may change; the official sources prevail. Regulations, Australian Standards and safety requirements change, and errors can occur, so have a licensed electrician assess your situation in person before acting on anything here. Electrical work in Queensland must only be done by a licensed electrician. If you think something here is wrong or out of date, call 0421 333 034 or email byron@knightes.au and we'll review it. To the extent permitted by law, Knight Electrical Solutions accepts no liability for loss or damage arising from reliance on this information.