Gold Coast – fixed price – 24/7
Smoke alarms only help if they're the right type, in the right places, and talking to each other. Our licensed electricians install interconnected photoelectric alarms to Queensland's requirements at a fixed price.
Alarm going off and you can smell smoke?Get everyone out first, then call 000.
Call 0421 333 034By 1 January 2027, every Queensland home needs interconnected photoelectric smoke alarms. That includes owner-occupied homes, not just rentals and sales.
They go in every bedroom, in hallways joining bedrooms to the rest of the home, and on every storey.
Not sure what you've got? We'll check your alarms and quote a fixed price before work starts.
Read our QLD smoke alarm guide or why a smoke alarm keeps beeping.
Most jobs start with a walk through the house. What's already on the ceiling decides whether you need hardwired or battery alarms.
240V photoelectric alarms, interconnected and tested. Required if your home already has hardwired alarms.
Sealed 10-year battery alarms that link without new cabling, for homes with battery alarms now.
Ionisation and expired alarms swapped for compliant ones, in every place the law requires.
Our QLD smoke alarm guideAlarms checked against the rules before a new tenancy, a lease renewal or a sale.
Landlord safety checksFalse alarms, chirping and dead units tracked down and fixed.
Why alarms beepFaulty wiring to hardwired alarms traced and repaired, then the alarms retested.
From the Queensland Fire Department and the Queensland Government. The deadline for every home is 1 January 2027.
All existing private homes, townhouses, units and manufactured homes need interconnected photoelectric smoke alarms by 1 January 2027. Owner-occupiers included.
Source: Smoke alarms, qld.gov.au
If you're selling, renting or re-renting, compliant interconnected photoelectric alarms must already be installed. This has applied since 1 January 2022.
Source: Early responsibilities for new home owners, qld.gov.au
In every bedroom, in hallways joining bedrooms to the rest of the home, and on every storey. A storey with no bedrooms needs one on the most likely path out.
Source: Queensland Fire Department
Photoelectric, compliant with AS 3786-2014, with no ionisation sensor. Look for the standard printed on the alarm.
Source: Queensland Fire Department
Homes with 240V alarms must replace them with 240V photoelectric alarms. Those must be connected by a licensed electrician.
Alarms older than 10 years, or that fail when tested, must be replaced. Check the date printed on yours.
A plain-English summary, not legal advice. Renting out a property? Read how often landlord electrical safety checks should happen in QLD.
Tell us how many bedrooms and storeys.
We check existing alarms, wiring and ceiling access.
One figure before work starts. No hourly rate.
Ionisation and expired alarms removed.
Installed, interconnected, and tested so they sound together.
EFTPOS on site when you're happy.
For larger jobs over $5,000 in materials that span multiple days, a deposit may be requested when the quote is accepted.
We price it after we've walked through the house. These are the things that move the number.
Landlords and strata
Landlords and property managers often have several homes to check, and rentals must already have compliant alarms. We quote each property at a fixed price before we start and work around tenant access.
We inspect first. The quote is the number you pay.
If our work fails, we come back and fix it.
Based in Palm Beach, so same-day is often possible.
QLD Electrical Contractor Licence, fully insured.
Residential, commercial and industrial work.
Paid on site when the job's done. No invoice to chase.
Director, Knight Electrical Solutions
20+ years in electrical work across Australia and New Zealand, including running his own business in Auckland.
Questions Gold Coast homeowners and landlords ask us about smoke alarms.
Yes. By 1 January 2027, all existing private homes, townhouses, units and manufactured homes in Queensland need interconnected photoelectric smoke alarms. That covers owner-occupied homes, not just rentals and homes being sold. If you're selling or renting, the rules already apply now. If your alarms are older ionisation types, not linked to each other, or more than 10 years old, they'll need replacing before the deadline.
Every bedroom, every hallway that joins bedrooms to the rest of the home, and every storey. If there's no hallway, the alarm goes between the bedrooms and the rest of that level. A storey with no bedrooms needs at least one alarm on the most likely path out of the home. Sloping ceilings and exposed beams have their own placement rules, so we check the layout on site.
No. The Queensland Fire Department says a home with 240V smoke alarms must replace them with 240V photoelectric alarms. Homes that only have battery alarms can use photoelectric alarms with a sealed 10-year battery instead. Either way, every alarm in the home must be interconnected so they all sound together. Hardwired alarms must be connected by a licensed electrician.
It depends on the home, so we don't give a price before we've seen it. The main factors are how many alarms the layout needs, whether your existing alarms are hardwired, how easy the roof space is to get into, and the condition of any existing alarm wiring. We walk through the house and give you one fixed price before work starts. You pay on completion by EFTPOS.
For hardwired alarms, yes. In Queensland, 240V smoke alarms connect to mains power and must be connected by a licensed electrician. Alarms with a sealed 10-year battery don't legally need an electrician, but they still have to be interconnected and placed in the right spots to comply. If your home already has hardwired alarms, the replacements must also be hardwired, which means calling an electrician.
The Queensland Fire Department recommends testing your alarms every month and cleaning off dust and insects with a vacuum or brush. Any alarm older than 10 years, or one that fails when tested, must be replaced, so check the date printed on yours. In a rental, the tenant must test and clean each alarm at least once every 12 months during the tenancy.
A rental must already have compliant interconnected photoelectric alarms. The owner or property manager must test the alarms and replace any flat or nearly flat batteries within 30 days before a tenancy starts or is renewed. They can't pass that job to the tenant. During the tenancy, the tenant tests and cleans each alarm at least every 12 months. We can upgrade alarms between tenancies.
Photoelectric alarms detect smoke with a light sensor. Ionisation alarms use a different sensor and no longer meet Queensland's rules. The Queensland Fire Department says compliant alarms must be photoelectric, meet AS 3786-2014 and must not contain an ionisation sensor. Check the label, which may be on the back of the alarm. If it mentions ionisation or doesn't show AS 3786-2014, it needs replacing.
Our electricians cover the whole Gold Coast and Tweed Heads.
We'll check your alarms and give you a fixed price to bring your home up to the 1 January 2027 rules.
0421 333 034
If anyone is in danger, has had an electric shock, or you can see fire, sparks or fallen powerlines, call Triple Zero (000) immediately. Don’t touch anyone who may be in contact with live electricity.
The information on this page is general and is not advice for your property. Summaries of Queensland law and standards are drawn from the official sources linked on this page, and may change; the official sources prevail. Regulations, Australian Standards and safety requirements change, and errors can occur, so have a licensed electrician assess your situation in person before acting on anything here. Electrical work in Queensland must only be done by a licensed electrician. If you think something here is wrong or out of date, call 0421 333 034 or email byron@knightes.au and we'll review it. To the extent permitted by law, Knight Electrical Solutions accepts no liability for loss or damage arising from reliance on this information.